Miller System 9A Specifikace Strana 61

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 80
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 60
59
www.milleruidpower.com
Heavy-Duty Hydraulic Cylinders
HV2 Series
Catalog HY08-M1140-3/NA
Miller Fluid Power
Des Plaines, IL
Milton, Ontario Canada
A
.50
.75
.75
.75
1.00
1.25
1.50
SAE
Dash
No.
8
12
12
12
16
20
24
Flange Ports (Code 61, 3000 psi) SAE 4 Bolt Flange Ports
Bore
Size
2.50
2 3
3.25
2
4.00
2
5.00
2
6.00
7.00
8.00
Y
2.39
2.80
3.17
3.05
3.05
3.42
3.17
3.17
3.42
3.42
3.42
3.52
3.70
3.84
W
.75
.94
.94
.94
1.03
1.16
1.37
Q
1.50
1.87
1.87
1.87
2.06
2.31
2.75
X
.34
.44
.44
.44
.52
.59
.70
AA
.81
.75
.75
.75
.87
1.00
1.06
SAE
Dash
No.
8
1
2
12
12
16
20
24
Bore
Size
2.50
2
3.25
2
4.00
2
5.00
2
6.00
7.00
8.00
Z
5/16 - 18
3/8 - 16
3/8 - 16
3/8 - 16
3/8 - 16
7/16 - 14
1/2 - 13
GG
.69
.87
.87
.87
1.03
1.19
1.41
P
2.97
3.41
3.66
4.16
4.58
5.59
6.31
Ports
Bore EE (NPTF) A (Dia.) B C D P
1.50 3/4 1.38 1.00 0.75 0.78 2.91
2.00 3/4 1.38 1.00 0.75 0.78 2.91
2.50 3/4 1.38 1.00 0.75 0.78 3.03
3.25 1 1.75 1.19 0.91 0.88 3.53
4.00 1 1.75 1.19 0.91 0.88 3.78
5.00 1 1.75 1.19 0.91 0.88 4.28
6.00 1 1/4 2.25 1.31 1.13 1.13 5.13
7.00 1 1/2 2.50 1.56 1.38 1.38 5.75
8.00 2 3.00 1.69 1.50 1.50 6.50
Bore EE (SAE) A (Dia.) B C D P
1.50 10
1
2.88
2.00 10
1
2.88
2.50 10
1
3.00
3.25 16 1.75 1.19 0.88 0.88 3.44
4.00 16 1.75 1.19 0.88 0.88 3.69
5.00 16 1.75 1.19 0.88 0.88 4.19
6.00 20
1
5.19
7.00 24
1
5.50
8.00 N/A 6.25
Y
A DIA.
X
GG
P + STROKE
Z UNC-2B THD.
AA MIN. DEPTH
4 HOLES
Q
W
Oversize Ports
Oversize NPTF or SAE straight thread ports can be
provided, at an extra charge. For ports one size larger
than standard, welded port bosses which protrude from
the side of the head or cap are supplied. For dimensions,
see drawings and tables below. HV2 Series cylinders
equipped with cushions at the cylinder cap end can
sustain damage to the cushion check valve (cushion
bushing) if excessive oil ow enters the cylinder from the
cap end port. Cylinders which are equipped with cap end
cushions and ordered with one size oversize ports having
hydraulic uid ow exceeding 25 ft./sec. in the line enter-
ing the cap end of the cylinder should be ordered with
a “solid cushion” at cap end. All cylinders ordered with
double oversize ports should always be ordered with a
“solid cushion” at cap end.
1
Port tapped directly into head and cap.
Oversize NPTF Port Boss Dimensions
Oversize SAE Straight Thread Port Boss Dimensions
Cylinders which are connected to a meter out ow control
with ow entering the cap end of a cylinder provided by an
accumulator may also experience damage to the cushion
bushing due to high instantaneous uid ows. This condi-
tion can be eliminated by using a meter in ow control or
“solid cushions” at cap end.
P + STROKE
EE
PORT
SIDE
A A
B
C
D
2
2.50", 3.25", 4.00" & 5.00" bores cap-ange port not available on Model 66.
Model 62 not available at position 2 or 4. Port ange overhangs cap on Model 68.
3
2.50" bore head ange port available with 1.000" rod only.
Zobrazit stránku 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 79 80